PR9112 Penentukuran Tekanan Pintar
Parameter Teknikal
| Model | PR9112Kalibrator Tekanan Pintar | |
| Pengukuran Tekanan | Julat Pengukuran | (-0.1~250)Mpa |
| Ketepatan paparan | ±0.05%FS, ±0.02%FS | |
| Pengukuran Arus Elektrik | Julat | ±30.0000mA |
| Kepekaan | 0.1uA | |
| Ketepatan | ±(0.01%R.D+0.003%FS) | |
| Pengukuran Voltan | Julat | ±30.0000V |
| Kepekaan | 0.1mV | |
| Ketepatan | ±(0.01%RD +0.003%FS) | |
| Nilai Penukaran | Sekumpulan pengukuran kuasa/gangguan kuasa | |
| Fungsi output | Output arus terus | DC24V±0.5V |
| Alam Sekitar Operasi | Suhu Kerja | (-20~50)℃ |
| Suhu Relatif | <95% | |
| Suhu Penyimpanan | (-30~80)℃ | |
| Konfigurasi Bekalan Kuasa | Mod bekalan kuasa | Bateri litium atau bekalan kuasa |
| Masa Operasi Bateri | 60 jam (24V tanpa beban) | |
| Masa pengecasan | Lebih kurang 4 jam | |
| Petunjuk lain | Saiz | 115mm×45mm×180mm |
| Antara muka komunikasi | palam penerbangan tiga teras khusus | |
| Berat | 0.8KG | |
Aplikasi Utama:
1. Kalibrasi pemancar tekanan (tekanan pembezaan)
2. Tentukur suis tekanan
3. Sahkan tolok tekanan ketepatan, tolok tekanan am.
Ciri Produk:
1. Fungsi pengendali manual terbina dalam, Pemancar tekanan pintar HART boleh dikalibrasi. (pilihan)
2. Paparan kristal cecair dua baris dengan lampu latar.
3.mmH2O、mmHg、psi、kPa、MPa、Pa、mbar、bar、kgf/c㎡, bertukar antara sembilan unit tekanan.
4. Dengan fungsi output DC24V.
5. Dengan pengukuran arus dan voltan.
6. Mengukur dengan menukar isipadu.
7. Dengan antara muka komunikasi. (pilihan)
8. Kapasiti storan: sejumlah 30 keping fail, (50 rekod data setiap fail)
9. Paparan cecair kristal skrin besar
Konfigurasi Perisian:
Perisian PR9112S bagi sistem pengesahan tekanan ialah perisian sokongan bagi sistem digital kamipenentukur tekananproduk siri di syarikat kami, Rekod pengumpulan data boleh dilakukan, Borang yang dijana secara automatik, Pengiraan ralat automatik, Cetak sijil.
1.Jadual Pemilihan Julat Tekanan Rutin
| Tidak. | Julat Tekanan | Jenis | Kelas ketepatan |
| 01 | (-100~0) kPa | G | 0.02/0.05 |
| 02 | (0~60)Pa | G | 0.2/0.05 |
| 03 | (0~250)Pa | G | 0.2/0.05 |
| 04 | (0 ~ 1) kPa | G | 0.05/0.1 |
| 05 | (0 ~ 2) kPa | G | 0.05/0.1 |
| 06 | (0 ~ 2.5) kPa | G | 0.05/0.1 |
| 07 | (0 ~ 5) kPa | G | 0.05/0.1 |
| 08 | (0 ~ 10) kPa | G | 0.05/0.1 |
| 09 | (0 ~ 16) kPa | G | 0.05/0.1 |
| 10 | (0 ~ 25) kPa | G | 0.05/0.1 |
| 11 | (0 ~ 40) kPa | G | 0.05/0.1 |
| 12 | (0 ~ 60) kPa | G | 0.05/0.1 |
| 13 | (0 ~ 100) kPa | G | 0.05/0.1 |
| 14 | (0 ~ 160) kPa | G/L | 0.02/0.05 |
| 15 | (0 ~ 250) kPa | G/L | 0.02/0.05 |
| 16 | (0 ~ 400) kPa | G/L | 0.02/0.05 |
| 17 | (0 ~ 600) kPa | G/L | 0.02/0.05 |
| 18 | (0 ~ 1) MPa | G/L | 0.02/0.05 |
| 19 | (0 ~ 1.6) MPa | G/L | 0.02/0.05 |
| 20 | (0 ~ 2.5) MPa | G/L | 0.02/0.05 |
| 21 | (0 ~ 4) MPa | G/L | 0.02/0.05 |
| 22 | (0 ~ 6) MPa | G/L | 0.02/0.05 |
| 23 | (0 ~ 10) MPa | G/L | 0.02/0.05 |
| 24 | (0 ~ 16) MPa | G/L | 0.02/0.05 |
| 25 | (0 ~ 25) MPa | G/L | 0.02/0.05 |
| 26 | (0 ~ 40) MPa | G/L | 0.02/0.05 |
| 27 | (0 ~ 60) MPa | G/L | 0.05/0.1 |
| 28 | (0 ~ 100) MPa | G/L | 0.05/0.1 |
| 29 | (0 ~ 160) MPa | G/L | 0.05/0.1 |
| 30 | (0 ~ 250) MPa | G/L | 0.05/0.1 |
Catatan: G=GasL=Cecair
2.Jadual Pemilihan Julat Tekanan Komposit:
| Tidak. | Julat Tekanan | Jenis | Kelas ketepatan |
| 01 | ±60 Pa | G | 0.2/0.5 |
| 02 | ±160 Pa | G | 0.2/0.5 |
| 03 | ±250 Pa | G | 0.2/0.5 |
| 04 | ±500 Pa | G | 0.2/0.5 |
| 05 | ±1kPa | G | 0.05/0.1 |
| 06 | ±2kPa | G | 0.05/0.1 |
| 07 | ±2.5 kPa | G | 0.05/0.1 |
| 08 | ±5kPa | G | 0.05/0.1 |
| 09 | ±10kPa | G | 0.05/0.1 |
| 10 | ±16kPa | G | 0.05/0.1 |
| 11 | ±25kPa | G | 0.05/0.1 |
| 12 | ±40kPa | G | 0.05/0.1 |
| 13 | ±60kPa | G | 0.05/0.1 |
| 14 | ±100kPa | G | 0.02/0.05 |
| 15 | (-100 ~160) kPa | G/L | 0.02/0.05 |
| 16 | (-100 ~250) kPa | G/L | 0.02/0.05 |
| 17 | (-100 ~400) kPa | G/L | 0.02/0.05 |
| 18 | (-100 ~600) kPa | G/L | 0.02/0.05 |
| 19 | (-0.1~1)Mpa | G/L | 0.02/0.05 |
| 20 | (-0.1~1.6)Mpa | G/L | 0.02/0.05 |
| 21 | (-0.1~2.5)Mpa | G/L | 0.02/0.05 |
Catatan:
1. Julat separa boleh melakukan tekanan sepenuhnya
2. Julat pampasan suhu automatik:(-20~50℃)
3. Medium pemindahan tekanan memerlukan bahan yang tidak menghakis